Page | 14 Revision 1.4 15 January
2015
External reference clock input
LabSat 3 features an external reference input for synchronization to a 10MHz clock. To use this feature,
connect a 10MHz reference signal with minimum +6dB level to the REF IN SMA connector and ensure that
the External 10MHz reference clock option is ticked in MENU SETUP CLK REF External 10MHz.
When the external reference input is enabled, the symbol will appear in the top right corner of the LCD.
Digital channels
There are 1 or 2 channels available for external digital data capture depending on the system variant and
the options that have been purchased with the LabSat. Recorded digital channel data is synchronized to
each sample of recorded RF data; the maximum input frequency for each channel is 1MHz. To record 2
digital channels, at least 2 RF channels must be selected or 1 single channel with 2-bit quantisation. The
Digital menu allows CH1 or CH2 (subject to LabSat variant) to be configured to record any of the following
parameters:-
Function
Description
Option or Standard
1PPS
This is the 1 Pulse Per Second output from the internal GNSS monitor and
will become active once the internal GNSS monitor has a position fix. Note,
that if using battery power with the power save option enabled, the GNSS
monitor will power-down after approx 30 seconds into the recording and
therefore not be present in the recorded data. During replay, the recorded
1PPS signal will be output on pin 2 (DIGO) of the expansion connector.
Standard
CAN
CAN 1 and CAN 2 on the expansion connector (RLACS202) will be recorded
on channel 1 & 2 of the LabSat 3. See section CAN BUS for more details.
Option on Single
constellation
variant*
RS232
This will record an RS232 level signal input on pin 18 of the expansion
connector. During replay, pin 17 of the expansion connector will output the
recorded data at RS232 level. Because the RS232 signal is digitized directly,
it is not necessary to configure baud rate.
Option on Single
constellation
variant*
DIGI
Will record the digital state of pin 3 of the expansion connector. During
replay, the signal will be re-created on pin 2 (DIGO) of the expansion
connector. See section EXPANSION CONNECTOR for more details.
Option on Single
constellation
variant*
*Contact Racelogic or your LabSat distributor to purchase upgrade options