Vista de pagina 24
RLVBMIM01 Mini Input Module
25 | 31/07/2009
Channel setup parameters
Each input channel has a Tab associated for configuring channel specific attributes.
The Digital input channels 1 & 2 also include a Mode option. Please see the section „Digital inputs‟ above for more details.
The Digital input channel 3 has a pulses per revolution option, which allows the configuration of this input as a dedicated RPM input.
Request and Response Identifiers
The Request Identifiers only have an effect in User Polled CAN Mode. If a CAN message is
received by the MIM01 that matches a Request Identifier then the MIM01 will respond by
sending the corresponding channel data on the corresponding Response Identifier. Note: All
channels can be set to the same Request Identifier, if desired this means that on receipt of a
single CAN message the MIM01 will respond with all channels of data. The Response
Identifiers MUST all be different.
In Timed Mode the channel data will be sent at intervals with the corresponding Response
Identifier the Request Identifiers have no effect.
When using Standard Identifiers the maximum value for the identifiers is $7FF. Entering a
value higher than this may result in unexpected results.