RLVBMIM01 Mini Input Module
6 | 31/07/2009
Standard Inventory
9way screw terminal input connector blocks
One of the following three cables.
VBOXMini to Mini input module cable
CAN Bus connecting cable (to Racelogic VBOX)
5 way Lemo to 6 way un-terminated cable (stand alone use)
Thermocouple inputs
The MIM01 has 2 K-type thermocouple inputs, each input is capable of measuring temperatures from 0-1000
0
C.
Each socket is the standard thermocouple socket format; the Green colour on a thermocouple plug indicates a K-type
thermocouple, +ve (green wire) on the thin spade terminal.
See the Specification table for full thermocouple specifications
Status lights:
Green light indicates a functioning thermocouple is connected.
Red light indicates no thermocouple connected or a problem with the thermocouple.
Analogue Inputs
All of the analogue inputs are non-opto isolated 14bit 0-14V inputs, and they are
all non-differential inputs that share the same ground.
An example of how to connect an isolated individual potentiometer is shown on the
right.
Connecting to a potentiometer already installed on a car, such as a throttle
potentiometer, would only require the output signal from the pot and the earth to
be connected to the MIM01 as the pot gets its power from the car.
Comentarios a estos manuales