LabSat Specifications
Output Signal Level
Adjustable -85dBm to -115dBm
Output Signal frequency
1575.420 MHz
Sampling frequency
16.368MHz
Bandwidth
4.092Mhz
Quantisation
1 bit
USB transfer rate
2.046Mbytes per second
Active Antenna Voltage Supply
3.3v
Reference Oscillator
16.368MHz Temperature controlled +/-0.5 ppm
Long term stability +/-1.0ppm
Optional OCXO Oscillator
16.368MHz Oven Controlled +/-0.5 ppb
Operating voltage
8v to 30VDC
Size
170mm x 128mm x 38mm
Weight
750g
LabSat Software Development Kit (SDK)
All LabSat functionality available through the graphical user interface is also made available by way of an API for customers to integrate into their own
production testing or laboratory environment.
The LabSat API is provided as a managed C# assembly requiring the Microsoft .Net 4.0 Client Profile runtime. As well as being accessible from managed
.Net code, the API is made COM visible allowing a wide range of programming environments to access the full LabSat API functionality. Samples are
provided in C#, Windows Powershell, VBScript and C++. A full description, code samples and manual are included with your LabSat software in the folder
located at C:\Program Files\Racelogic\LabSat 2\SDK\.